Tracked on [RSDEV-3195]

PR#13959 added a check that exposure is not too high. But if auto exposure is on, actual exposure (on some models) is not reflected to this field and we stop the calibration for no reason.
If AE is on we will not issue a warning about high exposure values.

@OhadMeir
OhadMeir requested a review from Nir-Az June 17, 2025 13:48

@Nir-Az Nir-Az left a comment

Copy link
Copy Markdown
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

LGTM

@OhadMeir
OhadMeir merged commit f912724 into realsenseai:development Jun 17, 2025