@Niosocket11

Smart current limit for drive motors is currently being calculated from this equation:
currentLimitAmps = neoFreeCurrentAmps + 2*motorTorqueLimitNewtonMeters / neoStallTorqueNewtonMeters * (neoStallCurrentAmps-neoFreeCurrentAmps);
The issue with this equation is that it assumes that the drive motor is a Neo which was earlier not a problem but now it is as we are not always using NEOs for drive but also NEO Vortex. I would suggest adding a MotorConfig to the SwerveConfig for both turn and drive to be able to more deterministically get values for the right motor type.