ROS 2 bringup and validation utilities for the HVL FR3 lab setup. The package currently provides reproducible dual-RealSense RGB bringup and an RViz configuration that shows both camera streams alongside the existing Franka MoveIt visualization.
- Ubuntu 24.04
- ROS 2 Jazzy
realsense2_camera4.57.7- librealsense 2.57.7
- Franka FR3 with gripper
- MoveIt Servo + SpaceMouse teleoperation
cd ~/franka_ros2_ws
source /opt/ros/jazzy/setup.bash
PYTHONNOUSERSITE=1 colcon build --packages-select fr3_lab_stack
source install/setup.bashIf CMake selects the Miniconda interpreter and reports missing ROS Python packages, rebuild once with:
PYTHONNOUSERSITE=1 colcon build --packages-select fr3_lab_stack \
--cmake-args -DPython3_EXECUTABLE=/usr/bin/python3Start both cameras:
ros2 launch fr3_lab_stack dual_realsense.launch.pyDefault configuration:
| Role | Serial | RGB topic |
|---|---|---|
| Wrist | 342222073510 |
/camera/wrist_camera/color/image_raw |
| External | 244222076317 |
/camera/external_camera/color/image_raw |
Both cameras use RGB8 at 1280x720x30. Depth, gyro, and accelerometer are disabled by default.
Enable depth when needed:
ros2 launch fr3_lab_stack dual_realsense.launch.py enable_depth:=trueThe cameras are not hardware synchronized. The launch keeps fixed serial-to-role binding but does not implement calibration, pairing, preprocessing, or policy inference.
Start the existing FR3 MoveIt stack:
ros2 launch franka_fr3_moveit_config moveit.launch.py \
robot_ip:=192.170.10.101 \
robot_type:=fr3 \
use_fake_hardware:=false \
load_gripper:=trueIn the running RViz session, use File → Open Config and load:
~/franka_ros2_ws/src/fr3_lab_stack/rviz/fr3_lab_stack.rviz
The project RViz configuration preserves the normal MoveIt visualization and adds:
- Wrist RGB
- External RGB
Start Servo:
ros2 launch igd_fr3_control fr3_spacemouse_servocontrol.launch.pyStart the SpaceMouse publisher:
ros2 run igd_fr3_control spacemouse_twiststamped_publisher \
--ros-args \
-p topic:=/servo_node/delta_twist_cmdsSee docs/commissioning.md for the integrated acceptance procedure.
Software build, launch, camera identity, optional depth, and RViz image-display checks have passed.
In the latest integrated observation on 2026-09-08, both RGB camera streams remained stable for 525.137 s at approximately 29.98 Hz, with no camera restart, disconnect, or new USB/xHCI error. The run was interrupted by a MoveIt Servo singularity safeguard before the required uninterrupted 15-minute acceptance period was completed.
After the monitored interval, the operator used MoveIt planning to move the arm to a nonsingular configuration and SpaceMouse teleoperation resumed. This supports interpretation of the event as expected singularity protection rather than a persistent Servo, controller, or communication failure.
The final uninterrupted 15-minute physical acceptance run remains pending.