Skip to content

Remove INSTRUCTION event monitoring will remove LINE events as well #109156

Description

@gaogaotiantian

Bug report

Bug description:

The current de-instrumentation code for instructions incorrectly de-instruments line too. So if INSTRUCTION events are removed, event if the LINE events are still there, it won't trigger the event.

importsysE=sys.monitoring.eventsdefline(*args):
print("Line event: ", args)
definst(*args):
print("Instruction event: ", args)
sys.monitoring.use_tool_id(0, "test")
sys.monitoring.set_events(0, 0)
sys.monitoring.register_callback(0, E.LINE, line)
sys.monitoring.register_callback(0, E.INSTRUCTION, inst)
sys.monitoring.set_events(0, E.LINE|E.INSTRUCTION)
sys.monitoring.set_events(0, E.LINE)
a=1sys.monitoring.set_events(0, 0)

CPython versions tested on:

CPython main branch

Operating systems tested on:

Linux

Linked PRs