dmitriy-myz added a commit to dmitriy-myz/python-validity that referenced this pull request May 28, 2026
Two changes, big payoff: AAB0 #0 went from 243/250 to 250/250 byte-exact
on the captured Wine enrollment frame. Average across 9 AAB0s improved
from ~94% to ~98%.
1. FILL was 128 (= the Q0 mid-gray byte value). DLL pads its 3×3 tiles
with Q16 mid-gray = 0x800000 (= 8388608). Using 128 propagated through
the doh convolution chain to non-padding pixels and changed NMS
results in EDGE TILES (rows 2 and cols 2 of the 3×3 grid). With the
fix, my port's tile 8 is byte-exact with captured F250 tile 8.
2. Corner-tile tightening in _a960_passes_global_edge: for tile
(i=GRID-1, j=GRID-1) — bottom-right — cap gy at oy + last_row_step
(= 102 exclusive for 112-px frame). Without this, my port keeps
7 tile-8 kps with gy in [102, 108] that DLL drops. Empirically
derived from 9-AAB0 enrollment capture; the kp orientation of these
kps and the per-AAB0 gy_max in DLL's tile 8 (range 82-101) suggests
the actual rule may be more nuanced (per-frame variable), but the
exclusive `gy < oy + step` empirically catches most edge cases for
the captured data.
Per-AAB0 byte-exact (gx, gy) match after fix:
#0: 250/250 #1: 239/250 #2: 239/250 #3: 243/250 #4: 244/250
uunicorn#5: 248/250 uunicorn#6: 249/250 uunicorn#7: 246/250 uunicorn#8: 246/250
Residual drift (1-11 per frame) is concentrated in TILE 8 (corner)
where DLL applies a per-frame gy cut whose rule isn't yet pinned down.
For example AAB0 #1 DLL keeps only 3 of ~12 high-resp tile-8 kps;
DLL's kept kps have gy ≤ 82 while my port's only_mine kps have gy
in [89, 101]. The cut isn't strict top-N or fixed gy threshold.
Diagnostic tools added:
dev/find_edge_bound.py - per-tile bound aggregator across all
AAB0s (lists observed gx/gy ranges)
dev/try_per_tile_bound.py - tests a per-tile bound filter against
my port's output